Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Nanomaterials (Basel) ; 14(7)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38607147

RESUMO

Field emission (FE) necessitates cathode materials with low work function and high thermal and electrical conductivity and stability. To meet these requirements, we developed FE cathodes based on high-quality wrinkled multilayer graphene (MLG) prepared using the bubble-assisted chemical vapor deposition (B-CVD) method and investigated their emission characteristics. The result showed that MLG cathodes prepared using the spin-coating method exhibited a high field emission current density (~7.9 mA/cm2), indicating the excellent intrinsic emission performance of the MLG. However, the weak adhesion between the MLG and the substrate led to the poor stability of the cathode. Screen printing was employed to prepare the cathode to improve stability, and the influence of a silver buffer layer was explored on the cathode's performance. The results demonstrated that these cathodes exhibited better emission stability, and the silver buffer layer further enhanced the comprehensive field emission performance. The optimized cathode possesses low turn-on field strength (~1.5 V/µm), low threshold field strength (~2.65 V/µm), high current density (~10.5 mA/cm2), and good emission uniformity. Moreover, the cathode also exhibits excellent emission stability, with a current fluctuation of only 6.28% during a 4-h test at 1530 V.

2.
ACS Appl Mater Interfaces ; 16(2): 2932-2939, 2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-38179712

RESUMO

Black silicon (BS), a nanostructured silicon surface containing highly roughened surface morphology, has recently emerged as a promising candidate for field emission (FE) cathodes in novel electron sources due to its huge number of sharp tips with ease of large-scale fabrication and controllable geometrical shapes. However, evaluating the FE performance of BS-based nanostructures with high accuracy is still a challenge due to the increasing complexity in the surface morphology. Here, we demonstrate a 3D modeling methodology to fully characterize highly disordered BS-based field emitters randomly distributed on a roughened nonflat surface. We fabricated BS cathode samples with different morphological features to demonstrate the validity of this method. We utilize parametrized scanning electron microscopy images that provide high-precision morphology details, successfully describing the electric field distribution in field emitters and linking the theoretical analysis with the measured FE property of the complex nanostructures with high precision. The 3D model developed here reveals a relationship between the field emission performance and the density of the cones, successfully reproducing the classical relationship between current density J and electric field E (J-E curve). The proposed modeling approach is expected to offer a powerful tool to accurately describe the field emission properties of large-scale, disordered nano cold cathodes, thus serving as a guide for the design and application of BS as a field electron emission material.

3.
ACS Omega ; 8(50): 48326-48335, 2023 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-38144075

RESUMO

Recently, there have been reports of lead halide perovskite-based sensors demonstrating their potential for gas sensing applications. However, the toxicity of lead and the instability of lead-based perovskites have limited their applications. This study addressed this issue by developing a H2S gas sensor based on a lead-free CsCu2I3 film prepared using a one-step CVD method. The sensor demonstrated excellent sensing properties, including a high response and selectivity toward H2S, even at low concentrations (0.2 ppm) at room temperature. Furthermore, a reasonable sensing mechanism was proposed. It is suggested that the sensing mechanism sheds light on the role of defects in perovskite materials, the impact of H2S as an electron donor, and the occurrence of reversible chemical reactions. These findings suggest that lead-free CsCu2I3 has great potential in the field of H2S gas sensing.

4.
Eur J Med Res ; 28(1): 72, 2023 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-36755332

RESUMO

BACKGROUND: The currently preferred minimally invasive approaches have substantially improved outcomes of infected walled-off pancreatic necrosis (iWON). However, iWON with deep extension (iWONde) still poses a tricky challenge for sufficient necrosis evacuation by one stand-alone approach, often requiring repeated interventions. The aim of this study was to assess the effectiveness and safety of a minimal-access video-assisted retroperitoneal and/or transperitoneal debridement (hereafter called VARTD) in the management of iWONde. METHODS: Patients who had developed an iWONde were recruited to receive the VARTD in this prospective single-arm study. The primary efficacy endpoint was clinical improvement up to day 28 after the VARTD, defined as a ≥ 75% reduction in size of necrotic collection (in any axis) on CT and clinical resolution of sepsis or organ dysfunction. The primary safety endpoint was a composite of major complications or death during follow-up. Six-month postdischarge follow-up was available. RESULTS: Between July 18, 2018, and November 12, 2020, we screened 95 patients with necrotizing pancreatitis; of these, 21 iWONde patients (mean [SD] age, 42.9 [11.7] years; 10 [48%] women) were finally enrolled. The primary efficacy endpoint was achieved by most participants (14/21, 67%). No participants required repeated interventions. The primary safety endpoint occurred in six patients (29%). Except one in-hospital death attributable to repeated intra-abdominal hemorrhage, others were discharged without any major complication. CONCLUSIONS: The VARTD approach appears to have a reasonable efficacy with acceptable complication rates and thus might be an option for improving clinical management of iWONde. TRIAL REGISTRATION: This study is registered with Chinese Clinical Trial Registry (chictr.org.cn number, ChiCTR1800016950).


Assuntos
Pancreatite Necrosante Aguda , Adulto , Feminino , Humanos , Masculino , Assistência ao Convalescente , Desbridamento , Drenagem , Mortalidade Hospitalar , Pancreatite Necrosante Aguda/cirurgia , Alta do Paciente , Estudos Prospectivos , Resultado do Tratamento , Cirurgia Vídeoassistida
5.
J Inflamm Res ; 16: 183-196, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36686275

RESUMO

Purpose: In order to further study the biological functions of glutathione peroxidases (GPXs) and their expression level in patients with osteoarthritis (OA), we fully explored the potential relationship between GPXs and OA. This will provide new ideas for basic biological studies and therapeutic strategies for OA patients. Patients and Methods: In this study, bioinformatics techniques were used to explore the biological functions of five GPXs. The core genes related to the biological functions of GPXs were identified by constructing a protein-protein interaction network (PPI). In addition, we utilized microarray data in public databases to analyze the expression levels of GPXs in OA patients and healthy controls. Finally, we used quantitative real-time polymerase chain reaction (qRT-PCR) to detect the expression of GPXs in OA patients and controls to validate our bioinformatic analysis results. Results: Enrichment analysis showed GPXs were mainly enriched in the glutathione metabolic pathway and participate in the biological process of oxidative stress response, and further play an antioxidant role. The PPI network indicated that superoxide dismutase 1 (SOD1), superoxide dismutase 2(SOD2) and catalase (CAT) were the core proteins of this network. GPX1 was regulated by the greatest number of miRNAs. Experiments showed that the expression of GPX1 was elevated in OA patients compared with controls. Conclusion: GPXs play an important antioxidant role in oxidative stress response. The expression of GPX1 was elevated in peripheral blood mononuclear cells (PBMCs) of OA patients. The changes of GPXs in OA patients may regulate the level of oxidative stress, which may influence synovial lesions and chondrocyte apoptosis.

6.
Surg Endosc ; 36(11): 8121-8131, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35469092

RESUMO

BACKGROUND: Indocyanine green (ICG) fluorescence staining is one of the most challenging procedures for laparoscopic anatomic liver resection (LALR). Here, we introduce a novel method based on the "hepatic pedicle first" approach that can improve the success rate of positive staining. METHOD: The target hepatic pedicle (even for the subsegment) was dissected through the first porta until it became visible. Five milliliters of 0.025 mg/ml ICG was injected after the target hepatic pedicle (extra-Glissonian approach) or portal vein/hepatic artery (intra-Glissonian approach) was punctured successfully using scalp acupuncture under direct vision. Then, the Glissonian pedicle or vessel was clamped immediately to prevent the intrahepatic diffusion of ICG. During the operation, a fluorescence imaging model was used repeatedly to confirm the segmental boundary. RESULTS: Finally, 24 patients underwent LALR with the "hepatic pedicle first" approach for ICG fluorescence-positive staining. In 5 patients, ICG-positive staining failed, representing a 79.17% success rate. The average staining time was 25.92 min ± 14.64 min. There were no complications associated with vessel puncture (bile leakage, hemorrhage, and thrombosis). CONCLUSION: The "hepatic pedicle first" approach is a feasible, convenient, and safe method for ICG-positive staining, with a high success rate.


Assuntos
Laparoscopia , Neoplasias Hepáticas , Humanos , Verde de Indocianina , Neoplasias Hepáticas/cirurgia , Hepatectomia/métodos , Laparoscopia/métodos , Coloração e Rotulagem
7.
Phys Chem Chem Phys ; 23(38): 22078-22085, 2021 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-34570850

RESUMO

The discovery of ferromagnetism in monolayer transition metal halides exemplified by CrI3 has opened a new avenue in the field of two-dimensional (2D) magnetic materials, and more such 2D materials are waiting to be explored. Herein, using an unbiased structure search combined with first-principles calculations, we have identified a novel CuCl2 monolayer, which exhibits not only intrinsic ferromagnetism but also auxetic mechanical properties originating from the interplay of lattice and Cu-Cl tetrahedron symmetries. The predicted Curie temperature of CuCl2 reaches ∼47 K, and its ferromagnetism is associated with the strong hybridization between the Cu 3d and Cl 3p states in the configuration. Moreover, upon biaxial tensile strain or carrier doping, the CuCl2 monolayer can be converted from ferromagnetic to non-magnetic and from half-metal to metal. These properties endow this CuCl2 monolayer with great potential for applications in auxetic/spintronic nanodevices.

8.
Sci Rep ; 11(1): 17971, 2021 09 09.
Artigo em Inglês | MEDLINE | ID: mdl-34504248

RESUMO

Rheumatoid arthritis (RA) is an autoimmune disease associated with advanced joint dysfunction. Madhuca indica J. F. Gmel, from the family Sapotaceae, is an Indian medicinal plant reported to have an array of pharmacological properties. The aim of present investigation was to determine the anti-arthritic potential of an isolated phytoconstituent from methanolic leaf extract of Madhuca indica (MI-ALC) against FCA-induced experimental arthritis. Polyarthritis was induced in female rats (strain: Wistar) via an intradermal injection of FCA (0.1 mL) into the tail. Polyarthritis developed after 32 days of FCA administration. Then rats were treated orally with an isolated phytoconstituent from MI-ALC at doses of 5, 10, and 20 mg/kg. Findings suggested that High-Performance Thin-Layer Chromatography, Fourier-Transform Infrared Spectroscopy, and Liquid Chromatography-Mass Spectrometry spectral analyses of the phytoconstituent isolated from MI-ALC confirmed the structure as 3,5,7,3',4'-Pentahydroxy flavone (i.e., QTN). Treatment with QTN (10 and 20 mg/kg) showed significant (p < 0.05) inhibition of increased joint diameter, paw volume, paw withdrawal threshold, and latency. The elevated synovial oxidative stress (Superoxide dismutase, reduced glutathione, and malondialdehyde) and protein levels of Tumor necrosis factor-α (TNF-α) and Interleukin (ILs) were markedly (p < 0.05) reduced by QTN. It also effectively (p < 0.05) ameliorated cyclooxygenase-2 (COX-2), Nuclear factor of kappa light polypeptide gene enhancer in B cells (NF-kß) and its inhibitor-α (Ikßα), and ATP-activated P2 purinergic receptors (P2X7) protein expressions as determined by western blot analysis. In conclusion, QTN ameliorates FCA-induced hyperalgesia through modulation of elevated inflammatory release (NF-kß, Ikßα, P2X7, and COX-2), oxido-nitrosative stress, and pro-inflammatory cytokines (ILs and TNF-α) in experimental rats.


Assuntos
Antirreumáticos/administração & dosagem , Artrite Experimental/tratamento farmacológico , Artrite Reumatoide/tratamento farmacológico , Flavonoides/administração & dosagem , Madhuca/química , Fitoterapia/métodos , Extratos Vegetais/administração & dosagem , Plantas Medicinais/química , Adjuvantes Imunológicos/efeitos adversos , Administração Oral , Animais , Antirreumáticos/química , Antirreumáticos/isolamento & purificação , Artrite Experimental/induzido quimicamente , Artrite Experimental/metabolismo , Artrite Reumatoide/induzido quimicamente , Artrite Reumatoide/metabolismo , Ciclo-Oxigenase 2/metabolismo , Citocinas/metabolismo , Feminino , Flavonoides/química , Flavonoides/isolamento & purificação , Adjuvante de Freund/efeitos adversos , Hiperalgesia/induzido quimicamente , Hiperalgesia/tratamento farmacológico , Hiperalgesia/metabolismo , Estrutura Molecular , NF-kappa B/metabolismo , Estresse Nitrosativo/efeitos dos fármacos , Extratos Vegetais/química , Extratos Vegetais/isolamento & purificação , Ratos , Ratos Wistar , Transdução de Sinais/efeitos dos fármacos , Resultado do Tratamento
9.
Contrast Media Mol Imaging ; 2021: 2529936, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34377103

RESUMO

This study was to explore the risk factors and prognosis of early neurological deterioration (END) after intravenous thrombolysis in patients with cerebral ischemic stroke (CIS) with the guidance of magnetic resonance imaging (MRI) under the compressed sensing-MRI (CSMRI) algorithm. 187 patients with CIS in the hospital were selected and grouped into a deterioration group and a control group according to whether they had END. The CSMRI algorithm was constructed and compared with digital television (DTV) algorithm and Bayesian compressed sensing (BCS) algorithm. It was found that the reconstruction time of CSMRI algorithm in platform I (1134.9 s) and platform II (2615.8 s) was visibly lower than that of DTV algorithm (2634.6 s, 3963.4 s) and BCS algorithm (5631.5 s, 7412.3 s), showing statistically obvious differences (P < 0.05). In addition, the reconstruction efficiency of the CSMRI algorithm was the best. After 4 hours of intravenous thrombolysis, the stroke scale score (12.3 scores) of the deterioration group was much higher than that of the control group (8.4 scores) (P < 0.05). The occlusion of responsible great vessel in the deterioration group (30 cases, 83.33%) was obviously higher in contrast to that in the control group (74 cases, 49%) (P < 0.05). Stroke scale score and occlusion of responsible great vessel were risk factors for EBD after intravenous thrombolysis.


Assuntos
Algoritmos , Isquemia Encefálica/terapia , AVC Isquêmico/terapia , Imageamento por Ressonância Magnética/métodos , Doenças do Sistema Nervoso/diagnóstico , Terapia Trombolítica/efeitos adversos , Teorema de Bayes , Isquemia Encefálica/patologia , Estudos de Casos e Controles , Feminino , Seguimentos , Humanos , AVC Isquêmico/patologia , Masculino , Pessoa de Meia-Idade , Doenças do Sistema Nervoso/induzido quimicamente , Doenças do Sistema Nervoso/etiologia , Resultado do Tratamento
10.
Phys Chem Chem Phys ; 23(27): 14671-14677, 2021 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-34223600

RESUMO

Given the highly possible existence of nickel and silicon in the Earth's core, the study of the reaction between Ni and Si and the resulting structures at the pressure corresponding to that of the Earth's core is highly required. Therefore, we have investigated the crystal structures of Ni-Si compounds at pressures of 0-350 GPa by adopting a crystal structure search algorithm in conjunction with first-principles calculations. We uncover two high Ni-content Ni5Si and Ni6Si compounds with 12-coordination Si bonded with Ni, with both showing strong chemical stability in the Earth's core. Bonding analysis reveals that the Ni atoms in these Ni-Si compounds present oxidant features and act as electron acceptors. This distinctive anomaly is the natural result of the energy shifts of the Ni 3d and Si 3p bands, resulting in charge transfer from Si to Ni. By examining the key properties (e.g., density and sound velocities) of the Ni5Si and Ni6Si compounds, the obtained density lies within the range of the Earth's inner core, and the estimated sound velocities are found to be consistent with seismic data. These results indicate that these two compounds could be considered as possible core constituents. Our findings provide valuable insights into the enigmatic Earth's core as well as geophysical and geochemical processes.

11.
Rev Esp Enferm Dig ; 113(2): 145-146, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33228370

RESUMO

We present the case of a gallbladder-abscess cavity fistula in a 46-year-old male with walled-off pancreatic necrosis (WOPN). A step-up approach was used for two months, which consisted of a minimally invasive necrosectomy followed by postoperative percutaneous lavages with two drainage tubes. The range of the abscess was significantly reduced, as shown by the computerized tomography scan (Fig. 1). However, a substantial amount of odorless, pale yellow, feculent fluid (almost 1,000 ml daily) was discharged from the drainage tubes over the following days, without lavages.


Assuntos
Fístula do Sistema Digestório , Pancreatite Necrosante Aguda , Drenagem , Humanos , Masculino , Pessoa de Meia-Idade , Necrose/etiologia , Pancreatite Necrosante Aguda/diagnóstico por imagem , Pancreatite Necrosante Aguda/cirurgia , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Resultado do Tratamento
12.
Med Hypotheses ; 141: 109733, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32305814

RESUMO

Currently, open surgical necrosectomy is only performed when the step-up approach fails in patients with necrotizing pancreatitis. As a common complication after surgery, external pancreatic fistula often leads to a long hospital stay and increased expenditure. Current therapeutic strategies include conservative management; however, unresponsive patients with pancreatic leaks will frequently require interventions. Existing evidence indicates that endoscopic transpapillary stenting can shorten the duration of external pancreatic fistula; however, the length of conservative treatment in the early stage cannot be avoided. Therefore, endoscopic transpapillary stenting cannot play a decisive role in the treatment and prevention of postsurgical external pancreatic fistula. The authors propose that endoscopic transpapillary stenting before surgery, however, can be used to prevent and treat postsurgical external pancreatic fistula and complications caused by the prolonged maintenance of the drainage tube for abscesses, including retrograde infection, through its physiological drainage effect. This hypothesis has important clinical implications for the accelerated postoperative recovery of patients with necrotizing pancreatitis.


Assuntos
Fístula Pancreática , Pancreatite Necrosante Aguda , Endoscopia , Humanos , Pâncreas , Pancreatite Necrosante Aguda/complicações , Pancreatite Necrosante Aguda/cirurgia , Resultado do Tratamento
13.
Nanomaterials (Basel) ; 10(4)2020 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-32316341

RESUMO

A highly conductive three-dimensional (3D) graphene network (GN) was fabricated by chemical vapor deposition on a 3D nickel fiber network and subsequent etching process. Then a lightweight and flexible polydimethylsiloxane (PDMS)/GN composite was prepared by a vacuum infiltration method by using the graphene network as a template. The composite showed the superior electrical conductivity of 6100 S/m even at a very low loading level of graphene (1.2 wt %). As a result, an outstanding electromagnetic interference (EMI) shielding effectiveness (SE) of around 40 and 90 dB can be achieved in the X-band at thicknesses of 0.25 and 0.75 mm, respectively, which are much higher than most of the conductive polymers filled with carbon. The 3D graphene network can also act as a mechanical enhancer for PDMS. With a loading level of 1.2 wt %, the composite shows a significant increase by 256% in tensile strength.

14.
IEEE Trans Neural Netw Learn Syst ; 31(5): 1514-1528, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31265414

RESUMO

With exploiting contextual information over large image regions in an efficient way, the deep convolutional neural network has shown an impressive performance for single-image super-resolution (SR). In this paper, we propose a new deep convolutional network by cascading multiple well-designed inception-residual blocks within the deep Laplacian pyramid framework to progressively restore the missing high-frequency details in the low-resolution images. By optimizing our network structure, the trainable depth of our proposed network gains a significant improvement, which in turn improves super-resolving accuracy. However, the saturation and degradation of training accuracy remains a critical problem. With regard to this, we propose an effective two-stage training strategy, in which we first use the images downsampled from the ground-truth high-resolution (HR) images to pretrain the inception-residual blocks on each pyramid level with an extremely high learning rate enabled by gradient clipping, and then the original ground-truth HR images are used to fine-tune all the pretrained inception-residual blocks for obtaining our final SR models. Furthermore, we present a new loss function operating in both image space and local rank space to optimize our network for exploiting the contextual information among different output components. Extensive experiments on benchmark data sets validate that the proposed method outperforms the existing state-of-the-art SR methods in terms of the objective evaluation as well as the visual quality.

15.
RSC Adv ; 10(36): 21615-21620, 2020 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-35518750

RESUMO

Surface charge-based nanopore characterization techniques unfold unique properties and provide a powerful platform for a variety of sensing applications. In this paper, we have proposed a nanoconfined inner wall surface charge characterization method with glass nanopores. The glass nanopores were functionalized with DNA aptamers that were designed for mercury (Hg2+) ion immobilization by forming thymine-Hg2+-thymine structures. The surface charge of the nanopores was modulated by surface chemistry and Hg2+ ion concentrations and analysed by combining zeta potential measurements on glass slides and the ionic current rectification ratio of the nanopores. Also, 1 pM Hg2+ ions could be detected by the nanopores.

16.
Nanomaterials (Basel) ; 9(12)2019 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-31817223

RESUMO

In this study, AlO(OH) (boehmite) film was deposited onto a surface acoustic wave (SAW) resonator using a combined sol-gel and spin-coating technology, and prepared and used as a sensitive layer for a high-performance ammonia sensor. The prepared AlO(OH) film has a mesoporous structure and a good affinity to NH3 (ammonia gas) molecules, and thus can selectively adsorb and react with NH3. When exposed to ammonia gases, the SAW sensor shows an initial positive response of the frequency shift, and then a slight decrease of the frequency responses. The sensing mechanism of the NH3 sensor is based on the competition between mass-loading and elastic-loading effects. The sensor operated at room temperature shows a positive response of 1540 Hz to 10 ppm NH3, with excellent sensitivity, selectivity and stability.

17.
Nanomaterials (Basel) ; 9(6)2019 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-31226830

RESUMO

H2S gas sensors were fabricated using p-n heterojunctions of NiO/ZnO, in which the ZnO nanorod arrays were wrapped with NiO nanosheets via a hydrothermal synthesis method. When the H2S gas molecules were adsorbed and then oxidized on the ZnO surfaces, the free electrons were released. The increase in the electron concentration on the ZnO boosts the transport speed of the electrons on both sides of the NiO/ZnO p-n junction, which significantly improved the sensing performance and selectivity for H2S detection, if compared with sensors using the pure ZnO nanorod arrays. The response to 20 ppm of H2S was 21.3 at 160 °C for the heterostructured NiO/ZnO sensor, and the limit of detection was 0.1 ppm. We found that when the sensor was exposed to H2S at an operating temperature below 160 °C, the resistance of the sensor significantly decreased, indicating its n-type semiconductor nature, whereas when the operating temperature was above 160 °C, the resistance significantly increased, indicating its p-type semiconductor nature. The sensing mechanism of the NiO/ZnO heterostructured H2S gas sensor was discussed in detail.

18.
Sci Adv ; 4(2): eaao6724, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29487906

RESUMO

The development of membrane technology is central to fields ranging from resource harvesting to medicine, but the existing designs are unable to handle the complex sorting of multiphase substances required for many systems. Especially, the dynamic multiphase transport and separation under a steady-state applied pressure have great benefits for membrane science, but have not been realized at present. Moreover, the incorporation of precisely dynamic control with avoidance of contamination of membranes remains elusive. We show a versatile strategy for creating elastomeric microporous membrane-based systems that can finely control and dynamically modulate the sorting of a wide range of gases and liquids under a steady-state applied pressure, nearly eliminate fouling, and can be easily applied over many size scales, pressures, and environments. Experiments and theoretical calculation demonstrate the stability of our system and the tunability of the critical pressure. Dynamic transport of gas and liquid can be achieved through our gating interfacial design and the controllable pores' deformation without changing the applied pressure. Therefore, we believe that this system will bring new opportunities for many applications, such as gas-involved chemical reactions, fuel cells, multiphase separation, multiphase flow, multiphase microreactors, colloidal particle synthesis, and sizing nano/microparticles.

19.
Sensors (Basel) ; 17(5)2017 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-28513538

RESUMO

Using a seed layer-free hydrothermal method, ZnO nanorods (NRs) were deposited on ST-cut quartz surface acoustic wave (SAW) devices for ammonia sensing at room temperature. For a comparison, a ZnO film layer with a thickness of 30 nm was also coated onto an ST-cut quartz SAW device using a sol-gel and spin-coating technique. The ammonia sensing results showed that the sensitivity, repeatability and stability of the ZnO NR-coated SAW device were superior to those of the ZnO film-coated SAW device due to the large surface-to-volume ratio of the ZnO NRs.

20.
J Hazard Mater ; 298: 154-61, 2015 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-26057440

RESUMO

In this report, NH3 gas sensors based on Ag-doped γ-Fe2O3/SiO2 composite films are investigated. The composite films were prepared with a sol-gel process, and the films' electrical resistance responded to the change of NH3 concentration in the environment. The SEM and AFM investigations showed that the films had a porous structure, and the XRD investigation indicated that the size of Ag particles changed with the modification of Ag loading content. Through a comparative gas sensing study among the Ag-doped composite films, undoped composite film, γ-Fe2O3 film, and SiO2 film, the Ag-doped composite films were found to be much more sensitive than the sensors based on the undoped composite film and γ-Fe2O3 film at room temperature, indicating the significant influences of the SiO2 and Ag on the sensing property. Moreover, the sensor based on Ag-doped (4%) γ-Fe2O3/SiO2 composite film was able to detect the NH3 gas at ppb level. Conversely, the responses of the sensor to other test gases (C2H5OH, CO, H2, CH4 and H2S) were all markedly low, suggesting excellent selectivity.


Assuntos
Amônia/análise , Compostos Ferrosos/química , Dióxido de Silício/química , Prata/química , Gases/análise , Microscopia Eletrônica de Varredura , Nanopartículas , Propriedades de Superfície , Temperatura , Difração de Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA